Dec. 12. 2017 | 繁中| 簡中


IP67 LED Lighting Driver
PFC Power Supplies
Telecom & Hybrid Inverter
E-Mobility Battery Charger
Adapter
Downloads
Contact Us

1.6KVA Ultra Compact Rack Mount Telecom Inverter with Parallel Connection Capability up to 51.2KW and Dual AC/DC Input Auto Selectable

DPI-1600
KEY FEATURES
 Hot swappable module with LED indicator
  Standard 19” 2U rack mount
  Zero transfer time
  DC Mode / AC Mode selectable
 High efficiency up to 97% at AC Mode
  Dual input source (AC & DC)
 Up to 32 modules can be connected in parallel (up to 51.2KW)
 Replacable fan module to make maintenance easy
 Input protection: Reverse Polarity / Under Voltage / Over Voltage
 Output protection: Short Circuit / Over Temperature
 Wide AC input range 75~132VAC (110VAC) / 150~265VAC (220VAC)
 CE / FCC approved
Model No. W/VA Size (mm)
D × W × H
Output Voltage (AC) Input Voltage (AC/DC) Working Temp (Degree C) Safety & EMC Accessories
DPI-1600-124 1200/1600 Module:
410×105×83; Shelf: 509x446x85
100 ~ 120 75 ~ 132/ 18 ~ 34 -25 ~ 40
(DC Mode);
-40 ~ 40
(AC Mode)
CE/FCC Standard 19” 2U 4 slots Redundancy Rack Mount Shelf with RS485 control interface
DPI-1600-148 1600/1600 75 ~ 132/ 36 ~ 68
DPI-1600-224 1200/1600 200 ~ 240 150 ~ 265/ 18 ~ 34
DPI-1600-248 1600/1600 150 ~ 265/ 36 ~ 68
2KVA Hybrid Inverter/ Charger with UL mark
SL-2000

image003
KEY FEATURES
Built-in self diagnosis microprocessor to identify and show failure messages on the LED, with associated visual/audio alarms; Battery charger current 100A max. @12VDC / 50A max. @24VDC; Equalization charging function for the batteries; Built in 50A @120VAC / 30A @240VAC bypass switch; Power sharing function; Intelligent software for power management; Hard-wire connection (option model); Fan controls by load and temperature; Local / remote management and control; RS-232 communication interface; Dry contact terminal; DC input over/ under voltage/ Internal over temperature/ battery over temperature/ device over temperature/ Inverter AC output overload/ Inverter AC output short circuit/ AC input short circuit Breaker (50Amp) @120VAC / (30Amp) @240VAC/ AC input under & over voltage protection
 
Electrical Specification Model No.
Item SL-2000-112 SL-2000-124 SL-2000-212 SL-2000-224
Inverter Mode  Input Characteristic  Nominal Voltage 12 VDC 24 VDC 12 VDC 24 VDC
Absolute max. DC input 25VDC 35VDC 25VDC 35VDC
HBCO/HBCI(High Battery Cut Out/In) 17 VDC±0.3V 34 VDC±0.3V 17 VDC±0.3V 34 VDC±0.3V
LBCO/LBCI(Low Battery Cut Out/In) 9.0 VDC±0.3V 18 VDC±0.3V 9.0 VDC±0.3V 18 VDC±0.3V
Input Voltage Range 9~17 VDC±0.3V 18~34 VDC±0.3V 9~17 VDC±0.3V 18~34 VDC±0.3V
Input Over-Voltage Protection 16.5 ~ 17 VDC 33 ~ 34 VDC 16.5 ~ 17 VDC 33 ~ 34 VDC
Input Under-Voltage Protection 9 ~ 10.5 VDC 18 ~ 21 VDC 9 ~ 10.5 VDC 18 ~ 21 VDC
Max. DC input current 267ADC 134ADC 267ADC 134ADC
No Load Power Consumption 25W
Stand-By Power Consumption < 5W
Output Characteristics   Continuous Output Power 2000 VA 
Surge Power(real watts) 5 sec 3400 (Tentative)
30 sec 3200 (Tentative)
5 min 2900 (Tentative)
30 min 2300 (Tentative)
Frequency 47 ~ 63 Hz ± 0.1Hz (User-selectable)
Output Voltage  120 VAC ± 5% 240 VAC ± 3%
(Continuous Power) (Continuous Power)
Max. Efficiency >90%
Short-Circuit Protection Yes 
Output Waveform Pure Sine Wave (THD < 5%) Pure Sine Wave (THD < 3%)
Charger Mode Charger Characteristics Battery Temperature protection By a RJ-11 connector to battery Temperature sensor
AC Input Voltage Range 80 ~ 140 VAC ± 5% 160 ~ 280 VAC ± 3%
(120VAC nominal) (240VAC nominal)
AC Input Frequency Range 47 ~ 63 Hz
AC Input Current Range 5 ~ 50A * 3 ~ 30A *
Charger Mode Charger Characteristics AC Nominal Current 15A 7.5A
Charger efficiency 85%
(peak)
Power Factor Correction(PFC) > 0.97 (50% Load)
Charging Current Range 0 ~ 100A 0 ~ 50A 0 ~ 100A 0 ~ 50A
Battery Temperature Compensation 25 mV per ℃ 50 mV per ℃ 25 mV per ℃ 50 mV per
Four-stage charging Bulk, Absorb, float, Equalize*
Equalization Characteristics Max. output Voltage 16VDC 32VDC 16VDC 32VDC
Max. output Current 10A 5A 10A 5A
Bypass switch Switch Specification(Max. each input) AC 50Amp AC 30Amp
Operating Temperature Range Full Load -20 ℃ ~ 40 ℃
Power de-rating 60 W / ℃, 41~60 ℃ (Tentative)
Storage -30 ℃~70 ℃
Over-temperature Protection Sensor on transformer, MOSFETs, battery, and internal ambient 
Operating Humidity Range 0~95% Non-condensing
Ground Relay Default setting is open. User may connect Neutral to ground at inverter mode if necessary, as ground relay is included in SL series.
Mechanical Specification Dimension 321X175X349mm / 12.64x6.89x13.74 inch
(W x H x D)
Net Weight 17.6 Kg (38.71 Lbs)
Safety and EMS Safety Standards UL458 EN60950-1
 EMC Standards FCC Class A EN55022:1998+A1:2000+A2:2003 Class A
EN55024:1997+A1:2001+A2:2003
EN61000-3-2:2006 Class A
EN61000-3-3:1995+A1:2001
   
Contact Us / Vendor Only / Darfon's Staff Only / Site Map